Codes and approvals referenced

CBC TABLE 721.1(2)CRC R302.3CRC R302.4).

Text on the drawing

5/8" TYPE 'X' GYP. BD., 6d COOLER NAILS @ 7" O.C. 2X4 STUDS AT 16" O.C. W/ 3-1/2" SOUND BATTS, SEE STRUCTURAL 5/8" TYPE 'X' GYP. BD., 6d COOLER NAILS @ 7" O.C. 1 HOUR PER CRC R302.3 (TWO-FAMILY / ATTACHED ADU); CBC TABLE 721.1(2) ITEM 14-1.3. EXTEND TO UNDERSIDE OF ROOF SHEATHING OR RATED CEILING. SEAL PENETRATIONS (CRC R302.4). N.T.S.