Preview of 1-hour exterior wall near property line detail. The DWG is fully editable.

Codes and approvals referenced

CBC TABLE 721.1(2)CRC TABLE R302.1(1))

Text on the drawing

WOOD STRUCTURAL PANEL WHERE OCCURS, SEE STRUCTURAL DRAWINGS 5/8" TYPE 'X' EXT. GYP. SHEATHING 7/8" EXT. CEMENT PLASTER OVER 2 LAYERS GRADE D PAPER 2X6 STUDS AT 16" O.C., SEE STRUCTURAL DRAWINGS 5/8" TYPE 'X' GYP. BD. 1 HOUR RATED, EXPOSURE FROM BOTH SIDES, WHERE < 5'-0" TO PROPERTY LINE (CRC TABLE R302.1(1)); CBC TABLE 721.1(2) ITEM 14-1.3. N.T.S.