TYPDETAIL

Home / Rated Assemblies

1-Hour Floor / Ceiling Between Dwelling Units Detail - typical rated assemblies detail drawing, DWG
Preview of 1-hour floor / ceiling between dwelling units detail. The DWG is fully editable.

Codes and approvals referenced

CRC R302.3

Text on the drawing

MIN. 23/32" T&G WOOD STRUCTURAL PANEL SUBFLOOR, SEE STRUCTURAL DRAWINGS 2X FLOOR JOISTS PER PLAN, 3-1/2" SOUND BATTS 5/8" TYPE 'X' GYP. BD. ON RESILIENT CHANNEL @ 16" O.C. 1 HOUR PER CRC R302.3 - LISTED UL / GA ASSEMBLY PER ARCH. PLANS; SUPPORTING WALLS ALSO 1 HOUR. STC 45 / IIC 45 MIN. WHERE REQUIRED BY LOCAL ORDINANCE. N.T.S.

More rated assemblies details

Non-Rated Floor - 2X Joists Detail - DWG drawing

Non-Rated Floor - 2X Joists Detail

Non-Rated Floor - I-Joists Detail - DWG drawing

Non-Rated Floor - I-Joists Detail

Non-Rated Floor - Trusses Detail - DWG drawing

Non-Rated Floor - Trusses Detail

Non-Rated Stc 58 Floor - 2X Joists Detail - DWG drawing

Non-Rated Stc 58 Floor - 2X Joists Detail

Non-Rated Stc 58 Floor - I-Joists with Lwc Detail - DWG drawing

Non-Rated Stc 58 Floor - I-Joists with Lwc Detail

Non-Rated Stc 61 Floor - 2X Joists with Lwc Detail - DWG drawing

Non-Rated Stc 61 Floor - 2X Joists with Lwc Detail

1-Hour Floor - 2X Joists Detail - DWG drawing

1-Hour Floor - 2X Joists Detail

1-Hour Floor - 2X Joists with 2 Layers WSP Detail - DWG drawing

1-Hour Floor - 2X Joists with 2 Layers WSP Detail