Preview of 1-hour stc 55 floor - trusses with lwc detail. The DWG is fully editable.

Text on the drawing

MIN. 23/32" WOOD STRUCTURAL PANEL SUBFLOOR, SEE STRUCTURAL DRAWINGS 1 1/2" LIGHTWEIGHT CONCRETE WOOD PARALLEL CHORD TRUSSES, MAX. 24" O.C., MIN. DEPTH 10", SEE STRUCTURAL DRAWINGS BATT INSULATION (OPTIONAL) 2 LAYERS 1/2" TYPE 'X' GYP. BD. 1 HOUR RATED AND STC 55 PER INTERTEK TESTING SERVICES, DESIGN No. TSC/FCA 60-10 N.T.S.