Attic Insulation Baffle at Eave - Section - typical roof framing detail drawing, DWG
Preview of attic insulation baffle at eave - section. The DWG is fully editable.

Codes and approvals referenced

CRC R806.2CRC R806.3)

Text on the drawing

RIGID / FOAM VENT BAFFLE, 1" MIN. AIR SPACE TO SHEATHING (CRC R806.3) CEILING INSULATION PER TITLE 24, FULL DEPTH OVER TOP PLATE VENTED BLOCKING / BIRD BLOCK CEILING JOIST / TRUSS BOTTOM CHORD 2X6 STUD WALL BAFFLE EACH RAFTER / TRUSS BAY; EXTEND ABOVE INSULATION. NET FREE VENT AREA PER CRC R806.2; KEEP EAVE VENTS UNOBSTRUCTED. N.T.S.