Codes and approvals referenced
Text on the drawing
BEAM PER PLAN (2) 1/4" x 5 1/2" STEEL SIDE PLATES (A36, HDG), ONE EA. FACE POST PER PLAN BOLT EDGE / END DISTANCES PER S-GEN-012. FULL BEARING OF BEAM ON POST; SHIMS STEEL ONLY. PLATES MAY BE REPLACED W/ LISTED POST CAP OF EQUAL OR GREATER CAPACITY. (2) 5/8" THRU-BOLTS TO BEAM, (2) TO POST, W/ STD. WASHERS (NDS 12.5) 1" = 1'-0"