Text on the drawing

8" MAX. BRICK VENEER, 3 5/8" NOM., RUNNING BOND 1" MIN. AIR SPACE 2" CONT. RIGID INSULATION ADJ. BRICK TIE @ 16" O.C. VERT., 24" O.C. HORIZ. MAX., SCREWED TO STUD (FIRST TIE 8" MAX.) WEEP VENTS @ 24" O.C. MAX. THRU-WALL FLASHING W/ DRIP EDGE CONC. BRICK LEDGE 600S162-43 CFS STUDS @ 16" O.C. (OR PER PLAN) W/ BATT INSULATION 5/8" GYP. BD. 1/2" EXT. GYPSUM SHEATHING AIR/WATER BARRIER, CONT. FROM FOUNDATION TO ROOF, LAP OVER LEDGE & UNDER FLASHING 600T125-43 TRACK W/ SILL SEALER & 0.145" PAF @ 16" O.C. CFS FRAMING PER AISI S240; BRICK VENEER & TIES PER TMS 402 / CBC CH. 14. CI AND AIR/WATER BARRIER PER CEC / SPECS. VERIFY STUD SIZE & SPACING FOR WIND AND VENEER LOADS W/ ENGINEER. CONC. SLAB / FOUNDATION PER PLAN N.T.S.