Preview of cast-in strap holdown at slab edge detail. The DWG is fully editable.

Codes and approvals referenced

STHD14

Text on the drawing

16" EMBED (2) 2X END POST SIMPSON STHD14 STRAP HOLDOWN, (30) 16d SINKERS TO POST P.T. SILL W/ 5/8" A.B. @ 32" O.C. #4 TOP & BOT. CONT. STHD14 SHOWN AS TYPICAL; ALLOWABLE LOAD PER SIMPSON CATALOG (REDUCED AT CORNERS). DO NOT BEND STRAP MORE THAN ONCE. NAIL ALL HOLES ABOVE SILL. STRAP EMBEDDED, SET BEFORE POUR & SECURED TO FORM FOOTING W/ (2) #4 CONT. N.T.S.