Text on the drawing
2' MAX. 8" CMU, GROUT SOLID, f'm = 1500 PSI #4 HORIZ. @ 16" O.C. (BOND BEAMS) FREE-DRAINING GRAVEL W/ FILTER FABRIC 4" PERF. PIPE TO DAYLIGHT OR WEEP HOLES @ 48" O.C. #4 @ 24" O.C. TRANSV. (3) #4 CONT. LONGIT. 2500 PSI CONC. FOOTING CAP BLOCK TYPICAL FOR LEVEL BACKFILL, NO SURCHARGE, 1500 PSF ALLOWABLE SOIL BEARING, EFP 30 PCF. VERIFY WITH SOILS REPORT AND ENGINEER FOR OTHER CONDITIONS. #4 @ 32" O.C. VERT. (CENTERED) W/ STD. 90 HOOK INTO FTG. N.T.S.