TYPDETAIL

Home / Roof Framing

Collar Tie at Rafters Detail - typical roof framing detail drawing, DWG
Preview of collar tie at rafters detail. The DWG is fully editable.

Codes and approvals referenced

CRC R802.4.6)

Text on the drawing

H/3 SPAN PER PLAN 2X6 @ 48" O.C. COLLAR TIE W/ (3) 10d EA. END TO EA. RAFTER 2X RIDGE BOARD, 1X MIN., DEPTH >= RAFTER CUT COLLAR TIES RESIST RIDGE UPLIFT ONLY (CRC R802.4.6); THEY DO NOT REPLACE RAFTER TIES OR A STRUCTURAL RIDGE. 1 1/4" X 20 GA. RIDGE STRAP @ 48" O.C. IS AN ACCEPTABLE ALTERNATE. 2X8 RAFTERS @ 16" O.C. W/ 15/32" WSP SHEATHING CEILING JOISTS / RAFTER TIES AT PLATE N.T.S.

More roof framing details

Shear Transfer, Roof Joist to Bearing Wall Detail - DWG drawing

Shear Transfer, Roof Joist to Bearing Wall Detail

2X Ridge Board Detail - DWG drawing

2X Ridge Board Detail

Shear Transfer, Perpendicular Rafter Detail - DWG drawing

Shear Transfer, Perpendicular Rafter Detail

Heel Connection (lap) Detail - DWG drawing

Heel Connection (lap) Detail

Ridge-Rafter Connection Detail - DWG drawing

Ridge-Rafter Connection Detail

Ridge Block Detail - DWG drawing

Ridge Block Detail

Shear Transfer at Eave Detail - DWG drawing

Shear Transfer at Eave Detail

Ceiling Beam Ridge Support Detail - DWG drawing

Ceiling Beam Ridge Support Detail