Codes and approvals referenced
Text on the drawing
5" MIN. 7 3/4" MAX. 2X12 P.T. CUT STRINGER (NO. 2 OR BETTER) TREAD PER PLAN, (2) #10 x 3" SCREWS EA. STRINGER STRINGER SPAN, SPACING AND TREAD SPAN PER AWC DCA 6 OR ENGINEERED DESIGN; 3 STRINGERS MIN. AT 36" WIDE STAIRS. THROAT (MIN. REMAINING DEPTH) 5" PER AWC DCA 6. CUT ENDS FIELD-TREATED W/ PRESERVATIVE. 1" = 1'-0"