Text on the drawing
1/2" MIN. 2" MIN. DOOR JAMB BEYOND DOOR & THRESHOLD. SET THRESHOLD INTO FULL BED OF POLYURETHANE SEALANT FLOOR FINISH - VERIFY W/OWNER NOTE: PRIME & PAINT ALL EXPOSED METAL FLASHING SURFACES SLOPE 10 MIL VAPOR BARRIER CONC. SLAB PROVIDE (MIN. 1/2") EXPANSION JOINT FELT DAMPPROOFING OVER CONC. 22 GA. G.I. SADDLE FLASHING - TURN DOWN EDGE N.T.S.