TYPDETAIL

Home / Repairs & Existing

Fire-Damaged Truss Repair Detail - typical repairs & existing detail drawing, DWG
Preview of fire-damaged truss repair detail. The DWG is fully editable.

Text on the drawing

SCRAPE CHARRED WD UNTIL SOUND FIBER IS REACHED. APPLY FIRE-RETARDANT SEALER TO EXPOSED WD AFTER REPAIR. REPAIR FIRE-DAMAGED TOP CHORD W/ (2) 2X6 SISTER MBRs (EA SIDE) EXTENDING MIN 3'-0" PAST DAMAGED AREA OR TO NEXT PANEL POINT. FASTEN W/ 10d NAILS @ 4" O.C. STAGGERED EA SIDE & APPLY CONST ADHESIVE BETWEEN MBRs. REMOVE ANY LOOSE OR BURNT TRUSS PLs & REINFORCE JOINT W/ (2) 3/4" PLYWD GUSSETS (EA SIDE) EXTENDING MIN 4'-0" BEYOND DAMAGED AREA. NAIL 10d @ 3" O.C. PERIM & 6" O.C. FIELD, STAGGERED EA FACE. APPLY CONST ADHESIVE BETWEEN GUSSET & TRUSS MBRs. NOTE: TRUSS REPAIR TO RESTORE ORIGINAL LOAD CAPACITY. ANY FIELD VARIATIONS SHALL BE REVIEWED BY ENGINEER OF RECORD. N.T.S.

More repairs & existing details

Infill at Former Garage Door Opening Detail - DWG drawing

Infill at Former Garage Door Opening Detail

Sister Joists - Repair Detail - DWG drawing

Sister Joists - Repair Detail

Fire-Damaged Top Plate Repair Detail - DWG drawing

Fire-Damaged Top Plate Repair Detail

Fire-Damaged Eave Repair Detail - DWG drawing

Fire-Damaged Eave Repair Detail

Infill at Existing Window Opening Detail - DWG drawing

Infill at Existing Window Opening Detail

Exterior Wall Section - Typical - DWG drawing

Exterior Wall Section - Typical

Ceiling Section - Typical - DWG drawing

Ceiling Section - Typical

Subfloor Replacement Notes - DWG drawing

Subfloor Replacement Notes