TYPDETAIL

Home / Stairs & Guards

Guard Height and Opening Limits - Elevation - typical stairs & guards detail drawing, DWG
Preview of guard height and opening limits - elevation. The DWG is fully editable.

Codes and approvals referenced

CBC 1607.9).CRC TABLE R301.5

Text on the drawing

42" MIN. 34" MIN. 4" SPHERE SHALL NOT PASS THRU GUARD OPENINGS 6" SPHERE AT STAIR TRIANGLE (RISER / TREAD / BOTTOM RAIL) GUARDS REQUIRED WHERE WALKING SURFACE > 30" ABOVE GRADE / FLOOR BELOW WITHIN 36" HORIZ. GUARD: 200 LB. CONC. LOAD AT TOP; INFILL 50 LB. ON 1 SQ. FT. (CRC TABLE R301.5, CBC 1607.9). 1/2" = 1'-0"