I-Joist Hanger - 14" I-Joist Detail - typical connections detail drawing, DWG
Preview of i-joist hanger - 14" i-joist detail. The DWG is fully editable.

Codes and approvals referenced

ESR-2549IUS2.56

Text on the drawing

SIDE VIEW FRONT VIEW HEADER / BEAM PER PLAN, DEPTH >= JOIST DEPTH FACE NAILS INTO HEADER, FILL ALL ROUND HOLES 1/8" MAX. GAP, JOIST TO HEADER 23/32" T&G SUBFLOOR, 8d @ 6" TO HEADER I-JOIST PER PLAN, SQUARE CUT END SIMPSON IUS2.56/14 W/ (10) 10d FACE, NO JOIST NAILS INSTALL PER SIMPSON STRONG-TIE CATALOG (ICC-ES ESR-2549). H = HANGER HEIGHT, 60% OF JOIST DEPTH MIN. USE HDG / ZMAX HANGER AND FASTENERS AT P.T. LUMBER. DO NOT SUBSTITUTE SCREWS FOR NAILS. N.T.S.