Text on the drawing
4 MIN. 2X6 STUDS @ 16" O.C. 2X6 BLOCKING BETWEEN STUDS AT LEDGER 15/32" WSP CONTINUOUS BEHIND LEDGER 24 GA. G.I. FLASHING, 4" MIN. UP WALL UNDER W.R.B. 15/32" WSP ROOF SHEATHING, B.N. 8d @ 6" O.C. TO LEDGER SIMPSON LRU28Z RAFTER HANGER EA. RAFTER 2X8 CONT. LEDGER, BEVEL TOP, (3) 16d INTO EA. STUD & (2) 16d @ 16" O.C. INTO BLOCKING RAFTER SPAN 12'-0" MAX. AT 20 PSF ROOF LIVE LOAD. WHERE WALL IS A SHEAR WALL, E.N. SHEATHING TO BLOCKING. LAP WEATHER BARRIER OVER FLASHING. PROVIDE HEADER BELOW LEDGER WHERE AN OPENING OCCURS. 2X8 RAFTERS @ 24" O.C. N.T.S.