Text on the drawing
1-1/2" MIN. BEARING KING STUD, FULL HEIGHT LVL BEAM / HEADER PER PLAN, END NAILED THRU KING STUD W/ (4) 16d WHERE REACTION EXCEEDS STUD CAPACITY, PROVIDE POST / COLUMN PER PLAN AND CARRY LOAD TO FOUNDATION. JACK STUD(S) PER PLAN (NUMBER PER REACTION) N.T.S.