TYPDETAIL

Home / Engineered Wood & I-Joists

LVL Beam / Header Bearing at Jack and King Studs Detail - typical engineered wood & i-joists detail drawing, DWG
Preview of lvl beam / header bearing at jack and king studs detail. The DWG is fully editable.

Text on the drawing

1-1/2" MIN. BEARING KING STUD, FULL HEIGHT LVL BEAM / HEADER PER PLAN, END NAILED THRU KING STUD W/ (4) 16d WHERE REACTION EXCEEDS STUD CAPACITY, PROVIDE POST / COLUMN PER PLAN AND CARRY LOAD TO FOUNDATION. JACK STUD(S) PER PLAN (NUMBER PER REACTION) N.T.S.

More engineered wood & i-joists details

I-Joist at Exterior Bearing - Blocking Panel Detail - DWG drawing

I-Joist at Exterior Bearing - Blocking Panel Detail

I-Joist at Exterior Bearing - I-Joist Rim Detail - DWG drawing

I-Joist at Exterior Bearing - I-Joist Rim Detail

I-Joist at Exterior Bearing - Rim Board Detail - DWG drawing

I-Joist at Exterior Bearing - Rim Board Detail

Rim Board Corner Connection - Plan - DWG drawing

Rim Board Corner Connection - Plan

I-Joist at Interior Bearing - Blocking Panel Detail - DWG drawing

I-Joist at Interior Bearing - Blocking Panel Detail

I-Joist Continuous over Interior Bearing Detail - DWG drawing

I-Joist Continuous over Interior Bearing Detail

I-Joists Lapped at Interior Bearing Detail - DWG drawing

I-Joists Lapped at Interior Bearing Detail

Blocking at Load-Bearing Wall Above Detail - DWG drawing

Blocking at Load-Bearing Wall Above Detail