Home / Engineered Wood & I-Joists

Text on the drawing
2-PLY: NAILED 3-PLY: NAILED / SCREWED 4-PLY: BOLTED / SCREWED (3) ROWS 16d @ 12" O.C. (2-PLY); BOTH SIDES AT 3-PLY 1/2" BOLTS OR 6" SDW SCREWS, 2 ROWS @ 24" O.C. STAGGERED SIDE-LOADED BEAMS (JOISTS / BEAMS HUNG ONE SIDE): FASTENER SCHEDULE PER MFR. SIDE-LOAD TABLES FOR THE REACTION; MIN. AS SHOWN. 7" WIDE MAX. FOR TOP-LOADED NAILED BEAMS. KEEP FASTENERS 2" FROM EDGES AND ENDS. N.T.S.
More engineered wood & i-joists details

I-Joist at Exterior Bearing - Blocking Panel Detail

I-Joist at Exterior Bearing - I-Joist Rim Detail

I-Joist at Exterior Bearing - Rim Board Detail

Rim Board Corner Connection - Plan

I-Joist at Interior Bearing - Blocking Panel Detail

I-Joist Continuous over Interior Bearing Detail

I-Joists Lapped at Interior Bearing Detail