Codes and approvals referenced
Text on the drawing
H = 5'-0" MAX. 2/3 H 24 GA. G.I. COPING OVER (2) 2X TOP PLATE 15/32" WSP EA. SIDE, 8d @ 6" E.N. / 12" F.N. 2X4 KICKER BRACE @ 48" O.C., 1:1 SLOPE, W/ SIMPSON A35 EA. END & (4) 16d TO STUD 2X4 FLAT PLATE ON ROOF W/ (3) 16d INTO BLOCKING BELOW 18" OPEN-WEB ROOF TRUSSES @ 24" O.C., TOP CHORD BEARING 2X6 BLOCKING BETWEEN TRUSSES W/ A35 EA. END 2X4 BLOCKING W/ Z-CLIPS BETWEEN TRUSS TOP CHORDS UNDER BRACE PLATE @ 48" O.C. PARAPET BRACED FOR SEISMIC OUT-OF-PLANE LOAD (ASCE 7 13.3). VERIFY TRUSS END DETAIL W/ TRUSS MFR. N.T.S.