Codes and approvals referenced
Text on the drawing
H/3 SPAN PER PLAN 2X RIDGE BOARD, 1X MIN., DEPTH >= RAFTER CUT 2X8 RAFTERS @ 16" O.C. W/ 15/32" WSP SHEATHING 1/2" GYP. BD. CEILING TIE LAPS RAFTER, NAILS STAGGERED, 3" O.C. MIN. RAFTER TIES RESIST RAFTER THRUST (CRC R802.5.2). CEILING JOISTS AT THE PLATE, LAPPED OVER BEARING WALLS, MAY SERVE AS TIES. NAIL COUNT PER TABLE R802.5.2 FOR SPAN, PITCH AND SNOW. 2X6 @ 16" O.C. RAFTER TIE W/ (5) 16d EA. END TO EA. RAFTER N.T.S.