Codes and approvals referenced
Text on the drawing
RAFTER / TRUSS PER PLAN 15/32" WOOD STRUCTURAL PANEL ROOF SHEATHING SIMPSON H8 TIE @ EACH RAFTER/TRUSS W/ (5) 10dX1-1/2 RAFTER (5) 10dX1-1/2 PLATE (2) 2X TOP PLATE STUD WALL PER PLAN UPLIFT / LATERAL TIE AT EACH RAFTER OR TRUSS U.N.O. INSTALL PER SIMPSON STRONG-TIE CATALOG (ICC-ES ESR-2613). TIE MAY BE INSTALLED ON EITHER FACE OF WALL; DO NOT BEND MORE THAN ONCE. 2X SOLID / VENTED BLOCKING BETWEEN RAFTERS (BEYOND) N.T.S.