FOUNDATION: CONC. PER STRUCT. ANCHOR BOLTS 1/2" X 10" @ 6'-0" O.C. MAX., 12" FROM PLATE ENDS (SEE FDN. DETAILS). FILL UNDER SLAB: 4" GRAVEL OR CRUSHED ROCK. SLABS: 4" CONC. W/ FIBERMESH, VAPOR RETARDER PER CRC R506. FLOOR JOISTS: 2X10 DF #2 @ 16" O.C. U.N.O. W/ SOLID BLOCKING AT BEARING POINTS. WALLS: 2X4 / 2X6 DF STUD @ 16" O.C., DBL. TOP PLATE, P.T. SILL. HEADERS PER PLAN. ROOF: TRUSSES / RAFTERS PER PLAN, 1/2" CDX SHEATHING; 220 LB. FIBERGLASS SHINGLES ON 15# FELT (OR AS SCHED.). GUTTERS & DOWNSPOUTS: PREFINISHED, TO SPLASH BLOCKS OR DRAIN SYSTEM. INTERIOR: 1/2" GYP. BD. WALLS, 5/8" TYPE X AT CEILINGS AND GARAGE SEPARATION CEMENT BD. AT WET AREAS. INSULATION / ENERGY: PER TITLE 24 CF1R. EXTERIOR: STUCCO OR SIDING PER ELEVATIONS OVER WRB. N.T.S.