Codes and approvals referenced
Text on the drawing
3'-0" MAX. 24 GA. G.I. COPING OVER MEMBRANE, SLOPE TO ROOF 15/32" WSP EA. SIDE OF PARAPET, 8d @ 6" E.N., 12" F.N. ROOFING TURNED UP 8" MIN. W/ CANT & COUNTERFLASHING 15/32" WSP ROOF SHEATHING, B.N. 8d @ 6" O.C. TO LEDGER I-JOIST BLOCKING @ 48" O.C. IN FIRST BAY 2X6 STUDS @ 16" O.C., CONT. TO TOP OF PARAPET 2X BLOCKING BETWEEN STUDS AT ROOF LINE W/ A35 CLIPS 15/32" WSP PER SHEAR WALL SCHEDULE 1 3/4" X 11 7/8" LVL LEDGER AGAINST STUDS W/ (3) 16d EA. STUD. PARAPET OVER 3'-0": BRACE PER PLAN. FIREBLOCK STUD BAYS AT ROOF LINE. PARAPET 30" MIN. WHERE REQUIRED FOR FIRE SEPARATION (CBC 705.11). 11 7/8" I-JOISTS PARALLEL TO WALL @ 24" O.C. N.T.S.