Text on the drawing

H = 6'-0" MAX. 2/3 H 24 GA. G.I. COPING OVER (2) 2X TOP PLATE 15/32" WSP EA. SIDE, 8d @ 6" E.N. / 12" F.N. 2X4 KICKER BRACE @ 48" O.C., 1:1 SLOPE, W/ SIMPSON A35 EA. END & (4) 16d TO STUD 2X4 FLAT PLATE ON ROOF W/ (3) 16d INTO BLOCKING BELOW 11 7/8" I-JOISTS PARALLEL TO WALL @ 24" O.C. 1 3/4" LVL RIM W/ A35 @ 24" O.C. I-JOIST BLOCKING PANELS @ 48" O.C. IN FIRST TWO JOIST BAYS, ALIGNED W/ BRACES, A35 EA. END TO JOIST FLANGES. PARAPET BRACED FOR SEISMIC OUT-OF-PLANE LOAD (ASCE 7 13.3). B.N. ROOF SHEATHING TO RIM AND BLOCKING. N.T.S.