TYPDETAIL

Home / Roof Framing

Roof Rafters to Glulam Beam Detail - typical roof framing detail drawing, DWG
Preview of roof rafters to glulam beam detail. The DWG is fully editable.

Codes and approvals referenced

A35H2.5A

Text on the drawing

15/32" WSP ROOF SHEATHING, B.N. 8d @ 6" O.C. INTO BLOCKING SIMPSON H2.5A UPLIFT TIE EA. RAFTER W/ (5) 8dX1-1/2 EA. END GLULAM BEAM 24F-V4 DF/DF PER PLAN I-JOIST RAFTERS: USE LVL BLOCKING AND SIMPSON VPA SLOPED BEARING CONNECTOR IN LIEU OF SEAT CUT. BLOCKING AND CLIPS TRANSFER DIAPHRAGM SHEAR TO BEAM WHERE BEAM IS A COLLECTOR. 2X10 RAFTERS @ 24" O.C. (OR PER PLAN) 2X BLOCKING (BEYOND) W/ A35 CLIP @ 24" O.C. TO BEAM N.T.S.