Text on the drawing
PLAN AT JOINT ELEVATION 3" x 6" x 0.036" (20 GA.) GALV. STEEL PLATE W/ (6) 8d NAILS EA. SIDE OF JOINT SINGLE 2X TOP PLATE RAFTER / JOIST CENTERED OVER STUD, 1" MAX. OFFSET 2X STUDS, PLATE JOINT OVER STUD SHOWN SINGLE TOP PLATE PER CRC R602.3.2 EXCEPTION. NOT PERMITTED AT BRACED WALL PANELS WITHOUT ENGINEERING. TOP PLATE MAY BE OMITTED OVER LINTELS ADEQUATELY TIED TO ADJACENT WALL SECTIONS W/ STEEL PLATES. 3" = 1'-0"