Text on the drawing
SAW-CUT CONTROL JOINT, 1/4 DEPTH, WITHIN 12 HRS, @ 12'-0" O.C. MAX. 4" 2500 PSI CONC. SLAB #3 @ 18" O.C. EA. WAY ON CHAIRS, CENTERED IN SLAB 2" CLEAN SAND 15 MIL VAPOR RETARDER (ASTM E1745 CLASS A), LAP & TAPE SEAMS 6" 4" CRUSHED ROCK CAPILLARY BREAK SUBGRADE COMPACTED TO 90% R.C. PER CRC R506 / CBC 1907. CURE 7 DAYS MIN. SOILS REPORT GOVERNS SUBGRADE PREP., VAPOR RETARDER AND ROCK THICKNESS. PROVIDE ISOLATION JOINTS AT COLUMNS. N.T.S.