Stair Stringer to Header - Lscz Connector Detail - typical stairs & guards detail drawing, DWG
Preview of stair stringer to header - lscz connector detail. The DWG is fully editable.

Codes and approvals referenced

CRC R318.7.5)

Text on the drawing

FLOOR HEADER / RIM PER PLAN SIMPSON LSCZ ADJ. STRINGER CONNECTOR EA. STRINGER W/ (4) 10d FACE, (4) 10d STRINGER 7 3/4" MAX. RISER, 10" MIN. TREAD (CRC R318.7.5) STRINGER CUT LEAVES 3 1/2" MIN. EFFECTIVE DEPTH. TREADS 2X P.T. OR 5/4 DECKING ON STRINGERS @ 16" O.C. MAX. GUARDS AT OPEN SIDES > 30" ABOVE GRADE. 2X12 STRINGER @ 16" O.C. MAX. (3 MIN. PER STAIR) N.T.S.