Text on the drawing
W-BEAM PER PLAN, (2) 3/16" FILLET WELD OR BOLTED TO PLATE (2) 3/4" HEADED ANCHORS / A.B. INTO GROUTED BOND BEAM, EMBED PER PLAN CMU BOND BEAM, SOLID GROUTED, (2) #4 CONT. + REINF. PER PLAN FULL BEARING UNDER PLATE; SHIM / DRYPACK W/ NON-SHRINK GROUT (5000 PSI MIN.). PROVIDE SLOTTED HOLES AT ONE END OF LONG BEAMS FOR THERMAL MOVEMENT. PRIME / PAINT EXPOSED STEEL. 3/4" BEARING PLATE (A36), SIZE PER PLAN, ON NON-SHRINK GROUT 1" = 1'-0"