Codes and approvals referenced
Text on the drawing
BEAM PER PLAN 1/4" CAP PL. W/ (4) 1/4" LAG SCREWS INTO BEAM, WELDED TO COLUMN 3" STD. STEEL PIPE COLUMN (ASTM A53 GR. B), CAP / BASE PLATES SHOP WELDED 1/2" BASE PL. W/ (2) 1/2" A.B., 7" EMBED SLAB FOOTING PER PLAN, MONOLITHIC W/ SLAB PRIME AND PAINT STEEL; HDG WHERE EXPOSED TO WEATHER. BASE PL. ON FOOTING; MAY BE SET IN SLAB BLOCKOUT ALT. (S-STL-042). COLUMN SIZE / HEIGHT PER PLAN. N.T.S.