Text on the drawing
5" MIN. 2" SQ. OR 1.9" O.D. STEEL POST NON-SHRINK GROUT, CROWNED TO SHED WATER A - CORED MOUNTING 1/2" X 6" X 6" PL., WELD ALL AROUND B - BASE PLATE MOUNTING (4) 3/8" WEDGE ANCHORS, 2 1/2" EMBED CORED HOLE 1" MIN. LARGER THAN POST, 5" MIN. DEEP, 4" MIN. FROM SLAB EDGE. WEDGE ANCHORS PER ICC-ES ESR LISTING, 6" MIN. EDGE DIST. GALV. OR PAINT STEEL AFTER INSTALL. N.T.S.