Text on the drawing

2 1/2" CONC. SLAB W/ 6X6-W1.4XW1.4 WWF ON 1 1/2" 20 GA. METAL DECK L4X4X3/8 CONT. LEDGER, DECK WELDED @ 12" O.C. 5/8" DIA. EXP. BOLTS @ 24" O.C. 4 1/2" EMBED (ICC-ES ESR) INTERMEDIATE BOND BEAM W/ (2) #5 8" CMU WALL BOLT INTO GROUTED BOND BEAM ONLY. LANDING DESIGNED FOR 100 PSF LIVE LOAD. EXP. BOLT EDGE DISTANCE AND CAPACITY PER ICC-ES ESR FOR BOLT IN GROUTED CMU. N.T.S.