Codes and approvals referenced
Text on the drawing
#15 ZINC CONTROL JOINT, LATH DISCONTINUOUS BEHIND JOINT 7/8" 3-COAT STUCCO 2 LAYERS GRADE D WRB SHEATHING PER PLAN STUDS @ 16" O.C. PANELS 144 SQ. FT. MAX., 18'-0" MAX. EITHER DIRECTION, LENGTH:WIDTH 2.5:1 MAX. (ASTM C1063); JOINTS AT OPENING CORNERS. CRC R703.7. N.T.S.