Suspended Plaster Ceiling at Wall Detail - typical rated assemblies detail drawing, DWG
Preview of suspended plaster ceiling at wall detail. The DWG is fully editable.

Codes and approvals referenced

ASCE 7 13ASTM C841CBC 1613).

Text on the drawing

CONC. SLAB / STRUCTURE ABOVE 8 GA. HANGER WIRE @ 4'-0" O.C. 1 1/2" MAIN RUNNERS @ 4'-0" O.C. 3/4" FURRING CHANNELS @ 12" O.C. W/ METAL LATH 7/8" CEMENT PLASTER (3 COAT) SEALANT / CASING BEAD 5/8" GYP. BD. ON METAL STUDS PLASTER CEILINGS PER ASTM C841 / C926. CONTROL JOINTS @ 10'-0" O.C. MAX. (100 SF PANELS). LATERAL BRACING OF SUSPENSION SYSTEM PER ASCE 7 13.5.6 (CBC 1613). N.T.S.