TYPDETAIL

Home / Walls & Shear Walls

Top Plate Splice Detail - typical walls & shear walls detail drawing, DWG
Preview of top plate splice detail. The DWG is fully editable.

Text on the drawing

TIE STRAP PER SCHEDULE. INSTALL PER MANUFACTURER'S INSTRUCTIONS (CENTER ON SPLICE JOINT) SPLICE ONLY (1) PLATE AT A TIME SPLICES SHALL BE 4'-0" O.C. MIN. (2) 2x OR 3x PLATES PROVIDE STUD AT SPLICE LOCATION WHERE REQUIRED NAILED TIE STRAP CL SPLICE PLATE 1/4" x 4" x 100" DIAMETER BOLT EACH SIDE OF SPLICE (2) 2x OR 3x PLATES ALTERNATE STRAP LOCATION SPLICE ONLY (1) PLATE AT A TIME SPLICES SHALL BE 4'-0" O.C. MIN. PROVIDE STUD AT SPLICE LOCATION WHERE REQUIRED BOLTED TIE STRAP NOTE: BOLT SPACING SHOWN FOR 3/4" DIAMETER BOLTS. SPACING=4D, END=7D N.T.S.