
Codes and approvals referenced
Text on the drawing
15/32" WSP ROOF SHEATHING W/ 8d @ 6" E.N., 12" F.N. PRE-MFR. TRUSS @ 24" O.C. PER TRUSS MFR. METAL CONNECTOR PLATE EA. FACE (BY TRUSS MFR.) SIMPSON H2.5A EA. TRUSS W/ (5) 8dX1-1/2 EA. END 15/32" WSP WALL SHEATHING, E.N. TO TOP PLATE 2X6 STUD WALL PER PLAN 1/2" GYP. BD. TRUSS DESIGN, BRACING AND GIRDER CONNECTIONS PER TRUSS MANUFACTURER (DEFERRED SUBMITTAL). PROVIDE 2X VENTED BLOCKING BETWEEN TRUSSES AT PLATE W/ A35 @ 24" O.C. WHERE WALL IS A SHEAR WALL. (2) 2X TOP PLATE N.T.S.







