Text on the drawing
EXT. FINISH PER PLAN 2x WOOD FRAMING MEMBER CIP ANCHOR BOLT, 7" MIN. EMBED. @ 6' O.C. MAX., 12" MAX. FROM ENDS & SPLICES 3"x3"x0.229" FOUNDATION PLATE WASHER 2x TREATED MUDSILL W/ SILL SEALER 3 1/2" CONCRETE SLAB W/ CONT. PERIMETER THICKENED END SLAB REINFORCING STEEL AS PER FOUNDATION PLAN 10 MIL. VAPOR BARRIER 4" GRAVEL (OPT. ADDITIONAL 2" SAND FILL RECOMMENDED) UNDISTURBED SOIL CONT. CONC. FOOTING W/ (1) #4 REBAR TOP & (2) #4 REBAR BTM. 3/4" = 1'-0"