Codes and approvals referenced
Text on the drawing
2x BLOCKING 2x STUDS TO PARAPET BOUNDARY NAILS PER PLAN 2x RIM JOIST. E.N. INTO RIM JOIST 7/8" 3-COAT STUCCO T.M.E. SHEATHING PER S-SHEETS 5/8" x 10" A.B. @ 4'-0" O.C. W/ 7" EMBEDMENT. 3" x 3" x 1/4" WASHERS 2x P.T. MUDSILL PARAPET FLASHING ROOF MEMBRANE O/ RIGID INSULATION O/ SHEATHING PER PLAN TOP FLANGE JOIST HANGER OR 2x LEDGER PER PLAN I-JOIST PER PLAN W/ R-38 EA. BAY 3/4" T&G FLOOR SHEATHING PER PLAN FLOOR JOISTS PER PLAN W/ R-30 EA. BAY TOP FLANGE JOIST HANGER OR A35 @ 24" O.C. PER PLAN 2x6 DF#2 @ 16" O.C. R-21 BATT EA. BAY (PER T-24) 5/8" TYPE "X" GYP. BD. 4" CONC. SLAB W/ REINF. PER PLAN O/ 10 MIL. VAPOR RETARDER O/ 4" BASE OF 1/2" OR LARGER AGG. CONT. CONC. FOOTING W/ (1) #4 TOP & (2) #4 BTM. PER PLAN FINISH GRADE, 8" MIN. CLEARANCE TO WOOD FRAMING N.T.S.