Codes and approvals referenced
Text on the drawing
TYPE SHEATHING EDGE NAIL FIELD NAIL SILL / A.B. ASD PLF 15/32" STR. I WSP ONE SIDE 8d @ 6" 8d @ 12" 16d @ 6" / 5/8" @ 48" 15/32" STR. I WSP ONE SIDE 8d @ 4" 8d @ 12" 16d @ 4" / 5/8" @ 32" 15/32" STR. I WSP ONE SIDE 8d @ 3" 8d @ 12" (2) 16d @ 6" / 5/8" @ 24" 15/32" STR. I WSP ONE SIDE 8d @ 2" 8d @ 12" (2) 16d @ 4" / 5/8" @ 16" 15/32" STR. I WSP BOTH SIDES 8d @ 3" 8d @ 12" SDS PER PLAN / 5/8" @ 12" 1/2" GYP. BD. 1 SIDE, BLK'D 5d CLR. @ 7" 5d @ 7" 16d @ 8" / 1/2" @ 72" VALUES PER AWC SDPWS-2021 TABLES 4.3A / 4.3C, SEISMIC ASD, DF-L FRAMING. ALL PANEL EDGES BLOCKED. 3X STUDS AND SILL AT ADJOINING PANEL EDGES WHERE NAILS ARE @ 3" O.C. OR LESS, OR BOTH SIDES SHEATHED. 3"X3"X0.229" PLATE WASHERS AT ALL A.B. 8d = 0.131"X2-1/2", 16d = 0.162"X3-1/2" COMMON NAILS. HOLDOWNS PER PLAN. WHERE PLAN IS MORE RESTRICTIVE, PLAN GOVERNS. N.T.S.
More general details

Braced Wall Lines and Panels - CRC R602.10 Detail

Common Wire Nail Sizes and Nail Loading Detail

Fireblocking and Draftstopping Detail

Mean Roof Height and Stories Above Grade Detail

Vertical Floor Offset - Shear Transfer Detail

Diaphragm Aspect Ratio and Opening Limits - Plan

Shear Wall Offsets and Segment Aspect Ratio Detail