Codes and approvals referenced
Text on the drawing
(2) SEISMIC STRAPS, UPPER AND LOWER 1/3 OF TANK (CPC 507.2), LAG TO STUDS WALL STUDS / BLOCKING WATER HEATER PER PLUMBING PLAN 3/4" PLYWOOD PLATFORM TOP 2X4 PLATFORM FRAMING @ 16" O.C., IGNITION SOURCE 18" MIN. ABOVE FLOOR (CPC 507.13) GARAGE SLAB PROVIDE IMPACT PROTECTION (BOLLARD) WHERE IN VEHICLE PATH (CPC 507.13.1). T&P DISCHARGE, PAN AND VENTING PER PLUMBING PLAN / MFR. N.T.S.