Text on the drawing
(2) 2X12 BEAM, SPLICE CENTERED OVER POST, 1 1/2" MIN. BRG. EA. SIMPSON BC4 / BC46 POST CAP W/ (12) 16d (OR PER PLAN) SIMPSON ST292 STRAP ACROSS SPLICE EA. SIDE W/ (12) 16d 4X POST PER PLAN STAGGER PLY SPLICES ONLY WHERE ALLOWED BY ENGINEER. PLIES NAILED W/ (2) ROWS 16d @ 12" O.C. STAGGERED. SPLICES NOT PERMITTED MID-SPAN. N.T.S.