Codes and approvals referenced
Text on the drawing
2x6 JOIST @ 12" O.C. L-BRACKET EA. SIDE OF EA. JOIST, ALL HOLES FILLED W/ 1 5/8" KIT BRACKET SCREWS. SEE NOTE FACTORY NOTCH, 3/4" MAX. DEEP, FULL WIDTH OF BEAM 4-PLY 2x6 BUILT-UP BEAM SECTION 3/4" MAX. 2x6 JOIST IN FACTORY NOTCH L-BRACKET EA. SIDE OF EA. JOIST ELEVATION NOTE: PROVIDE AN L-BRACKET EA. SIDE OF EA. JOIST AT EA. BEAM. WHERE THE KIT HAS A FACTORY BRACKET ON ONE SIDE ONLY, ADD A SIMPSON A34Z (IAPMO ER-112) ON THE OTHER SIDE W/ (8) SD9112 SCREWS (ESR-3046). 1 1/2" = 1'-0"