Text on the drawing
STUD WALL PER PLAN 15/32" WOOD STRUCTURAL PANEL (OR PER S.W. SCHED.) SILL PL NAILING 16d @ 6" O.C. U.N.O. B.N. 8d @ 6" O.C. NAIL SHEATHING INTO BLOCKING PANELS W/ 8d @ 6" O.C. 1 1/2" GYP. CONC. TOPPING 23/32" T&G WOOD STRUCTURAL PANEL FLOOR SHEATHING E.N. 8d @ 6" O.C. 1/8" GAP E.N. 8d @ 6" O.C. NAILS INTO END NAILER BLOCKS PER MANUFACTURER I-JOISTS PER PLAN I-JOIST BLOCKING PANELS @ 48" O.C. W/ END NAILER BLOCKS 1 3/4" LVL RIM NAIL BLOCKING PANEL TO PLATE W/ 10d @ 6" O.C. TOENAIL STUD WALL PER PLAN A35 SHEAR CLIPS @ 24" O.C. (AS REQUIRED) 15/32" WOOD STRUCTURAL PANEL (OR PER S.W. SCHED.) NOTE: SOLID SAWN JOIST AND BLOCKING SIMILAR. B.N. = BOUNDARY NAILING E.N. = EDGE NAILING B.N./E.N.: 8d @ 6" O.C. U.N.O. ADD 2X BLOCKING AS REQUIRED W/ (3) 8d TOENAILS EA. END N.T.S.