Codes and approvals referenced
Text on the drawing
1.5D 1.5D MIN. DISTANCE (FULL DESIGN VALUE) MIN. EDGE DISTANCE, l/D ≤ 6 1.5D LOADED EDGE (LOAD PERP. TO GRAIN) END DIST., PARALLEL, COMPRESSION END DIST., PARALLEL, TENSION (SOFTWOOD) SPACING BETWEEN BOLTS IN A ROW SPACING BETWEEN ROWS (PARALLEL LOAD) 1.5D BOLT (DIA. = D) IN HOLE 1/32"-1/16" OVERSIZE, STD. WASHER EA. END PER AWC NDS TABLES 12.5.1A - 12.5.1D (CBC 2302.1). REDUCED DISTANCES ONLY W/ GEOMETRY FACTOR PER NDS 12.5. LAG SCREWS 1/4" DIA. AND LARGER FOLLOW THE SAME LIMITS (D = SHANK DIA.). 1 1/2" = 1'-0"
More general details

Braced Wall Lines and Panels - CRC R602.10 Detail

Wall Sheathing / Shear Wall Schedule

Common Wire Nail Sizes and Nail Loading Detail

Fireblocking and Draftstopping Detail

Mean Roof Height and Stories Above Grade Detail

Vertical Floor Offset - Shear Transfer Detail

Diaphragm Aspect Ratio and Opening Limits - Plan