Text on the drawing
24" SQ. 32" MAX. 4X10 GIRDER P.T. 2X12 CAP PLATE W/ 1/2" DIA. A.B. IN GROUTED CELL 4" SOLID CAP BLOCK 8X8X16 CMU, TWO PER COURSE, ALTERNATE DIRECTION, TYPE S MORTAR; GROUT CELL AT A.B. 10 MIL VAPOR RETARDER OVER CRAWL FLOOR 24"X24"X8" FOOTING W/ (3) #4 EA. WAY, 3" CLR. UNREINFORCED PIER HEIGHT 4X LEAST DIMENSION MAX. (CRC R606.7); TALLER PIERS GROUTED W/ (2) #4 VERT. PIER SUPPORTS FLOOR LOADS ONLY: 6'-0" GIRDER SPACING X 6'-0" PIER SPACING AT 1500 PSF SOIL BEARING. N.T.S.