TYPDETAIL

Home / Foundations

CMU Pier on Footing at Crawl Space Detail - typical foundations detail drawing, DWG
Preview of cmu pier on footing at crawl space detail. The DWG is fully editable.

Codes and approvals referenced

CRC R606.7)

Text on the drawing

24" SQ. 32" MAX. 4X10 GIRDER P.T. 2X12 CAP PLATE W/ 1/2" DIA. A.B. IN GROUTED CELL 4" SOLID CAP BLOCK 8X8X16 CMU, TWO PER COURSE, ALTERNATE DIRECTION, TYPE S MORTAR; GROUT CELL AT A.B. 10 MIL VAPOR RETARDER OVER CRAWL FLOOR 24"X24"X8" FOOTING W/ (3) #4 EA. WAY, 3" CLR. UNREINFORCED PIER HEIGHT 4X LEAST DIMENSION MAX. (CRC R606.7); TALLER PIERS GROUTED W/ (2) #4 VERT. PIER SUPPORTS FLOOR LOADS ONLY: 6'-0" GIRDER SPACING X 6'-0" PIER SPACING AT 1500 PSF SOIL BEARING. N.T.S.

More foundations details

Typical Perimeter Footing Detail - DWG drawing

Typical Perimeter Footing Detail

Typical Interior Footing Detail - DWG drawing

Typical Interior Footing Detail

Typical Non-Bearing Wall to Concrete Slab Detail - DWG drawing

Typical Non-Bearing Wall to Concrete Slab Detail

Dowel into Existing Concrete Slab Detail - DWG drawing

Dowel into Existing Concrete Slab Detail

New Footing to Existing Footing Detail - DWG drawing

New Footing to Existing Footing Detail

Concrete Footing to Existing Slab Detail - DWG drawing

Concrete Footing to Existing Slab Detail

Concrete Slab to Existing Footing Detail - DWG drawing

Concrete Slab to Existing Footing Detail

Post Square Footing Detail - DWG drawing

Post Square Footing Detail