TYPDETAIL

Home / Foundations

CMU Stem Wall at Crawl Space Detail - typical foundations detail drawing, DWG
Preview of cmu stem wall at crawl space detail. The DWG is fully editable.

Codes and approvals referenced

CRC R408.1).

Text on the drawing

2X10 JOISTS @ 16" O.C. W/ 2X10 RIM P.T. 2X6 SILL W/ 1/2" A.B. @ 4'-0" O.C. IN GROUTED CELL, 7" EMBED 4" SOLID CAP BLOCK 8" CMU STEM WALL, #4 VERT. @ 48" O.C. IN GROUTED CELLS FINISH GRADE, SLOPE AWAY CRAWL SPACE GRADE W/ 6 MIL VAPOR RETARDER FOUNDATION VENTS 1 SQ. FT. PER 150 SQ. FT. OF CRAWL SPACE, WITHIN 3'-0" OF CORNERS (CRC R408.1). 18" MIN. GRADE TO JOISTS. FOOTING 12" MIN. BELOW GRADE ON UNDISTURBED SOIL, 1500 PSF BEARING. 24"X8" FOOTING W/ (2) #5 CONT. N.T.S.