Text on the drawing
TOOLED CONTROL JOINT, 1/4 DEPTH, @ 10'-0" O.C. MAX. EA. WAY 4" 2500 PSI CONC. (3000 PSI AT DRIVEWAYS), MEDIUM BROOM FINISH #3 @ 18" O.C. EA. WAY ON CHAIRS, MID-DEPTH 4" CLASS 2 AGG. BASE @ 95% R.C. SUBGRADE SCARIFIED & COMPACTED TO 90% R.C. (95% AT DRIVEWAYS) EXPANSION JOINT (1/2" PREMOLDED FILLER) AT BUILDINGS, CURBS AND @ 40'-0" O.C. MAX. SLOPE 2% MAX. CROSS SLOPE AT ACCESSIBLE ROUTES. SOILS REPORT GOVERNS. DETAIL # - CONCRETE SIDEWALK NOT TO SCALE