Concrete Stem Wall Foundation - 18" Stem Detail - typical foundations detail drawing, DWG
Preview of concrete stem wall foundation - 18" stem detail. The DWG is fully editable.

Codes and approvals referenced

CRC R403.1.

Text on the drawing

P.T. 2X6 SILL W/ 5/8" DIA. A.B. @ 48" O.C., 7" MIN. EMBED #4 VERT. @ 48" O.C. W/ STD. HOOK, ALT. HOOKS (1) #4 TOP CONT. 2500 PSI CONCRETE (2) #4 BOTTOM CONT., 3" CLR. FINISH GRADE, 6" MIN. CLR. TO WOOD PER CRC R403.1. FTG. BOTTOM 12" MIN. BELOW UNDISTURBED GRADE, 1500 PSF SOIL. 18" MIN. CRAWL SPACE CLR. TO JOISTS (12" TO GIRDERS). STEM OVER 24" HIGH: ADD #4 HORIZ. @ 12" O.C. N.T.S.