Text on the drawing
(3) 2X BOUNDARY STUD PACK EA. SIDE OF ROD 7/8" DIA. TIEDOWN ROD W/ COUPLER BEARING PLATE & SHRINKAGE TAKE-UP DEVICE P.T. 3X SILL PLATE W/ 5/8" DIA. A.B. @ 32" O.C. #4 HAIRPIN AROUND ROD, 24" LEGS INTO SLAB CAST-IN ROD W/ 1/2"X3" SQ. PLATE WASHER & DOUBLE NUT (4) #4 VERTICAL BARS AT ANCHOR (3) #3 TIES IN TOP 5" OF WALL 8" CONC. WALL, #4 @ 12" O.C. EA. WAY ROD SIZE, TAKE-UP DEVICE AND ANCHOR EMBEDMENT BY TIEDOWN MFR. PER SHEAR WALL UPLIFT. CENTER ANCHOR IN WALL; MAINTAIN 1 1/2" CLEAR COVER. SPECIAL INSPECTION OF ANCHOR PLACEMENT BEFORE POUR. N.T.S.