Codes and approvals referenced
Text on the drawing
8 3/4" EMBED (3) 2X BOUNDARY STUD PACK EA. SIDE OF ROD CONTINUOUS TIEDOWN SYSTEM (ATS): 7/8" DIA. THREADED ROD ROD COUPLER W/ WITNESS HOLES BEARING PLATE & SHRINKAGE TAKE-UP DEVICE PER MFR. P.T. 3X SILL W/ 5/8" A.B. @ 32" O.C. CAST-IN ANCHOR W/ 1/2"X3 1/2" SQ. PLATE WASHER & DOUBLE NUT 12" PODIUM SLAB & REINF. PER PLAN ROD SIZES, TAKE-UP DEVICES AND BEARING PLATES BY TIEDOWN MFR. PER SHEAR WALL UPLIFT (DEFERRED SUBMITTAL). SPECIAL INSPECTION OF ANCHOR PLACEMENT. ANCHOR REINF. PER ACI 318 17.5.2.9 WHERE REQ'D. N.T.S.
More foundations details

Typical Perimeter Footing Detail

Typical Interior Footing Detail

Typical Non-Bearing Wall to Concrete Slab Detail

Dowel into Existing Concrete Slab Detail

New Footing to Existing Footing Detail

Concrete Footing to Existing Slab Detail

Concrete Slab to Existing Footing Detail