TYPDETAIL

Home / Foundations

Continuous Tiedown Rod Anchor to Podium Slab Detail - typical foundations detail drawing, DWG
Preview of continuous tiedown rod anchor to podium slab detail. The DWG is fully editable.

Codes and approvals referenced

ACI 318

Text on the drawing

8 3/4" EMBED (3) 2X BOUNDARY STUD PACK EA. SIDE OF ROD CONTINUOUS TIEDOWN SYSTEM (ATS): 7/8" DIA. THREADED ROD ROD COUPLER W/ WITNESS HOLES BEARING PLATE & SHRINKAGE TAKE-UP DEVICE PER MFR. P.T. 3X SILL W/ 5/8" A.B. @ 32" O.C. CAST-IN ANCHOR W/ 1/2"X3 1/2" SQ. PLATE WASHER & DOUBLE NUT 12" PODIUM SLAB & REINF. PER PLAN ROD SIZES, TAKE-UP DEVICES AND BEARING PLATES BY TIEDOWN MFR. PER SHEAR WALL UPLIFT (DEFERRED SUBMITTAL). SPECIAL INSPECTION OF ANCHOR PLACEMENT. ANCHOR REINF. PER ACI 318 17.5.2.9 WHERE REQ'D. N.T.S.

More foundations details

Typical Perimeter Footing Detail - DWG drawing

Typical Perimeter Footing Detail

Typical Interior Footing Detail - DWG drawing

Typical Interior Footing Detail

Typical Non-Bearing Wall to Concrete Slab Detail - DWG drawing

Typical Non-Bearing Wall to Concrete Slab Detail

Dowel into Existing Concrete Slab Detail - DWG drawing

Dowel into Existing Concrete Slab Detail

New Footing to Existing Footing Detail - DWG drawing

New Footing to Existing Footing Detail

Concrete Footing to Existing Slab Detail - DWG drawing

Concrete Footing to Existing Slab Detail

Concrete Slab to Existing Footing Detail - DWG drawing

Concrete Slab to Existing Footing Detail

Post Square Footing Detail - DWG drawing

Post Square Footing Detail